SPECIFICATIONS
ASTM E1255 section 5.2 indicates that the purchaser and the
supplier of radioscopic examination systems must agree mutually upon
a written procedure with the applicable requirements. Other recommendations
are as follows:
- Equipment qualifications (system features that must be qualified
to ensure adequate performance).
- Test-object scan plan: Test-object orientations, motions, and speed
of manipulation necessary to ensure that the examination will be thorough.
- Radioscopic parameter (focal-spot size, source-to-object distance,
object-to-image plane distance, etc.).
- Image processing parameter (electronic noise reduction, contrast
enhancement).
- Image display parameters (brightness, contrast focus, and image
linearity).
- Accept/reject criteria (expected discontinuity types and rejection
levels).
- Performance evaluation (qualification tests to ensure system capabilities).
- Image archiving requirements (for preserving and recalling the image
at a later date).
- Minimum operator qualification.
 
|